Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Group: | All |
Still deciding? Get samples of US$ 8500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
l Excellent temperature control performance of the instrument, the maximum temperature rise and fall ≥5.0ºC/s.
l No edge effect, no optical path correction, top excitation/detection, non-contact measurement.
l Fluorescence detection adopts MPPC sensor with high sensitivity.
l Long-life LED light source, stable emission wavelength, maintenance-free.
l 4-channel fluorescence detection, no cross interference between channels.
l User-friendly and fully functional software, flexible program setting, comprehensive analysis and reporting functions, all the parameters can be stored.
The software includes functions such as absolute quantification experiment, melting curve experiment, relative quantification (AACT) experiment, and genotyping experiment. Enter the attribute setting interface and select different function modules. Guided flow operation, convenient for users to quickly complete experimental settings. The software can open the recent experiment record template for easy viewing of recent experiments and the creation of new experiments.
Product Name |
Fluorescence Quantitative PCR Detection System |
|||
Model |
LEIA-X4 |
|||
Sample Capacity |
96x0.1ml PCR plate, 12x8-strip tubes, 96*0.1ml single tube (Transparent Cover) |
|||
Reaction System |
10~50μl |
|||
Dynamics Range |
1-1010 copies |
|||
Channel |
4 |
|||
Emission Light |
LED |
|||
Detector |
MPPC |
|||
Detection Path |
F1 |
F2 |
F3 |
F4 |
Suitable Probe/Dye |
FAM/SYBR GREEN
|
VIC/JOE/ HEX/TET |
ROX/TEXAS-RED |
Cy5
|
Excitation Wavelength |
455~680nm |
|||
Detection Wavelength |
510~730nm |
|||
Fluorescence Detection Repeatability |
CV≤2% |
|||
Fluorescence Detection Accuracy |
CV≤3% |
|||
Fluorescence Detection Linearity |
r≥0.995 |
|||
Module Temp. Range |
4-99ºC(resolution:0.1ºC) |
|||
Ramp Rate |
5.0ºC/s(max) |
|||
Temp. Accuracy |
±0.3ºC |
|||
Temp. Uniformity |
≤ ±0.3ºC |
|||
Temp. Control Mode |
Block mode
|
|||
Gradient Temp. Range |
1-36ºC |
|||
Hot-Lid Temp. Range |
100ºC, Automatic Hot-lid |
|||
Scanning Mode |
Full plate scanning |
|||
Programming |
Max 100 Segments for Each Program, Max 99 Cycles |
|||
Operation Mode |
Continuous |
|||
Scanning Time |
8.5s |
|||
Special Function |
Absolute quantitative automatic analysis, relative quantification, SNP Analysis, melting curve analysis, etc. |
|||
Operation System |
Microsoft: Windows10 |
|||
Power Supply |
220V,50/60HZ; 110V,60HZ |
|||
Dimension(L*W*H) Mm |
375*490 *365 |
|||
Port Method |
USB Port |
|||
Packing Size(L*W*H) Mm |
645*565 *605 |
|||
Gross Weight |
45 |