| Customization: | Available |
|---|---|
| After-sales Service: | Online Technical Support |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




Model | BK-100HPLC(Type I) Isocratic manual system | BK-100HPLC(Type II) Gradient manual system | BK-100HPLC(Type III) Isocratic manual system | BK-100HPLC(Type IV) Gradient manual system | BK-100HPLC(Type V) Binary gradient manual system with PDA |
Software With Audit Trail | / | / | Yes | Yes | Yes |
Diode Array Detector | / | / | / | / | Yes |
High-pressure Constant Flow Pump | LC-100 HP*1 | LC-100 HP*2 | LC-100 HP*1 | LC-100 HP*2 | LC-100 HP*2 |
UV Detector LC-100 UV | Yes | Yes | Yes | Yes | / |
Diode Array Detector(With English Workstation) | / | / | / | / | LC-100 PDA*1 |
Workstation LC-100 WS | Yes | Yes | / | / | / |
Workstation EX-Clarity C50 | / | / | Yes | Yes | Yes |
Manual Sampler 7725i | Yes | Yes | Yes | Yes | Yes |
C18 5μm ID4.6*250mm | Yes | Yes | Yes | Yes | Yes |
High-precision Mixer EX1600 MX3 | / | Yes | / | Yes | Yes |
Power Supply | AC220/110V, 50/60Hz | ||||
Optional Accessory | UV detector, Rl detector, DAD100 detector, ELSD detector, FLD100 detector, column, column oven, ARCUS 5 auto-sampler | ||||
Package Size(W*D*H) | 450*620*350mm*2 | 450*620*350mm*3 | 450*620*350mm*2 | 450*620*350mm*3 | 450*620*350mm*2 660*560*500mm*1 |
Gross Weight | 34kg | 52kg | 34kg | 52kg | 56kg |
LC-100 HP High-Pressure Constant Flow Pump: | |
Liquid Infusion System | Dual-piston reciprocating parallel pump, equipped with a binary high-pressure mixer |
Flow Rate Range | 0.001~10ml/min |
Max Output Pressure | 42MPa |
Flow Accuracy | ≤±1% |
Flow Precision | RSD<0.07% |
Qualitative Repeatability | RSD6≤0.1%(naphthalene/methanol standards) |
Quantitative Repeatability | RSD6≤0.3%(naphthalene/methanol standards) |
Pressure Fluctuation | 0.1MPa |
Power Supply | AC220/110V, 50/60Hz |
LC-100 UV Detector: | |
Flow Cell Volume | 8.0μl |
Light Source | D2 lamp |
Wavelength Range | 190~680nm |
Spectrum Bandwidth | 8nm |
Wavelength Accuracy | ±1nm |
Wavelength Precision | Below 0.1nm |
Noise | ≤0.25x10-5.AU(static)/±1x10-5,AU(dynamic, under given conditions) |
Drift | ≤0.4x10-3AU/h(static)/≤2x10-3AU/h(dynamic, under given conditions) |
Minimum Detectable Concentration | 3x10-9g/ml(naphthalene/methanol solutio |
LC-100 PDA Detector: | |
Wavelength Range | 200~900nm(200~600*), Above 600nm just for W lamp |
Arrays | 512 |
Spectrum Bandwidth | 10nm |
Light Source | D2 lamp+W lamp |
Noise | ±5*10-5AU |
Sample Rate | Max100Hz |
Interface | LAN, USB, R232 |