• Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
  • Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
  • Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
  • Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
  • Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
  • Biobase Benchtop Conductivity Salinity Meter TDS pH Meter

Biobase Benchtop Conductivity Salinity Meter TDS pH Meter

After-sales Service: Online Support and Free Part
Warranty: 1 Year′s Warranty
Display: Digital
Portable: Non Portable
Appliance: Food Analysis, Medical Research, Biochemistry
Certification: /
Samples:
US$ 297/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Related Products
  • Company Profile
  • Contact Us
Overview

Basic Info.

Model NO.
PH-950
Conductivity Range
0~20.00, 200.0, 2000μs/Cm, 20.00, 200.0ms/Cm
Conductivity Accuracy
±0.5% F.S
TDS Range
0~100ppt (Max. 200ppt, Depending on Factor Setting
TDS Accuracy
±1% F.S
Salinity Range
0~10ppt (Max. 80ppt)
Salinity Accuracy
±1% F.S
Resistivity Range
0~100mΩ
Resistivity Accuracy
±1% F.S
Weight(Kg)
1.5kg
Package Size(W*D*H)mm
310*240*180mm
Transport Package
International Standard
Specification
TDS Meter
Trademark
BIOBASE
Origin
China
Production Capacity
200 Units/Month

Product Description

Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
Benchtop Conductivity/TDS/Salinity Meter EC Meter TDS Meter Price
 
Product Description

 

Product Overview:

High accuracy benchtop conductivity meter with TDS, salinity and resistivity measurement modes, 1 to 5 points calibration, automatic endpoint hold. Accuracy: 0.5% F.S.

1. Pictures of Benchtop Conductivity/TDS/Salinity Meter:
Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
Product Parameters

 


2. Parameters of Benchtop Conductivity/TDS/Salinity Meter:

Model

PH-950

Conductivity Range

0~20.00, 200.0, 2000μS/cm, 20.00, 200.0mS/cm

Conductivity Accuracy

±0.5% F.S

TDS Range

0~100ppt (Max. 200ppt, depending on factor setting)

TDS Accuracy

±1% F.S

Salinity Range

0~10ppt (Max. 80ppt)

Salinity Accuracy

±1% F.S

Resistivity Range

0~100MΩ

Resistivity Accuracy

±1% F.S

Calibration Points

1~5 points

Calibration Solutions

10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm

Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient

0.0~10.0%/°C

Normalization Temperature

20°C or 25°C

Cell Constant

K=0.1, 1, 10 or User-defined

Memory

Stores up to 500 data sets, USB Communication Interface

Power Requirements

DC5V/400mA power adapter

Dimensions(mm)

210*188*60mm

Weight(kg)

1.5kg

Package Size(W*D*H)mm

310*240*180mm

Gross weight(kg)

1.7kg


3. Features of Benchtop Conductivity/TDS/Salinity Meter:

* Multi-parameter conductivity meter contains the TDS, salinity and resistivity measurement modes.
* 1 to 5 points calibration with automatic calibration solution recognition.
* Selectable cell constant ( 0.1/1/10 ), normalization temperature ( 20°C or 25°C ),
* TDS conversion factor, seawater and practical salinity measurement modes.
* Linear or pure water compensation improves the measurement accuracy.
* Automatic Temperature Compensation ensures accurate reading.
* Calibration Due Reminder prompts user to calibrate the meter regularly.
* Stability indicator automatically shows current measurement status.
* Auto-Hold function freezes stable measured value for easy viewing and recording.
* Selectable temperature unit ( °C or °F ) meets different application requirements.
* Automatic electrode diagnosis shows cell constant of the conductivity electrode.
* Help message as a operational guide that helps you quickly begin using the meter.
* System menu allows setting the 11 parameters, including the temperature unit, number of calibration points, stability condition, etc.
* Reset feature automatically resumes parameters back to factory default options.
* Expanded memory stores and recalls up to 500 readings.
* Built-in real-time clock stamps stored data to meet GLP standard.
* Stored data can be transferred into computer by USB communication interface.
Accessories:
* Conductivity electrode
* Temperature probe
* Conductivity Standard Solutions (84μS/cm, 1413μS/cm, 12.88mS/cm)
* USB cable
* DC5V power adapter

 

Related Products

 

Biobase Benchtop Conductivity Salinity Meter TDS pH MeterBiobase Benchtop Conductivity Salinity Meter TDS pH MeterBiobase Benchtop Conductivity Salinity Meter TDS pH Meter
 
Company Profile

 

Company Overview:

Biobase Benchtop Conductivity Salinity Meter TDS pH Meter


Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
Biobase Benchtop Conductivity Salinity Meter TDS pH Meter
Biobase Benchtop Conductivity Salinity Meter TDS pH Meter



FAQ

1. How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
2. How about Biobase delivery time?
Within 7-15 workdays after receiving deposit.
3. How about Biobase validity of quotation?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
4. What's the shipping port?
FOB to Qingdao Port, China(also can ship according to customers' request)
5. How about the package?
Bubble film & cotton & standard export wooden case
6. How to inspect the goods?
Products will be checked by our QC staff first, then our project manager.
Client can come and check by themselves or by third party check is available.
Contact Us

 

Biobase Benchtop Conductivity Salinity Meter TDS pH Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now