• Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
  • Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
  • Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
  • Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
  • Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
  • Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab

Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab

Type: Water Quality Analyzer
Display: LED
Application: Agriculture & Food
Portable: Non-portable
Operating Mode: Touch Screen
Residual Chlorine: 0.05~5.00mg/L
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)

Basic Info.

Model NO.
BK-WQA-1
Total Chlorine
0.05~5.00mg/L
Ozone
0.05~2.50mg/L
Nitrite-N
0.01~0.40mg/L
Ammonia Nitrogen
0.05~10.0mg/L
Low Turbidity
0.5~60.0ntu
Total Phosphorus
0.01~1.00mg/L
Transport Package
Wooden Package
Specification
440*350*250mm
Trademark
BIOBASE
Origin
China
Production Capacity
500 Units Per Month

Product Description

Portable Multi-Parameter Water Quality Analyzer
It can be directly selected to measure COD, ammonia, total phosphorus, turbidity, color, hexavalent chromium, total chromium, nitrite nitrogen and other water quality testing indicators. It is widely used in environment protection, scientific research monitoring, production monitoring and other fields, and it's the ideal equipment for environment monitoring and controlling.Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab

Features:

*  Suitcase detector integrated design, easy to carry.

*  A single instrument can detect 3-99 parameters of water quality indicators.

*  Large full-color touch screen, Icon function keys.
*  Square sample cell, suitable for various kinds of cuvettes.

*  Manual modification, auto-calibration and auto-fitting.

*  RS232 interface (USB optional) , support exporting TXT or EXCEL format report.
 

NO.

Parameter Name

Measuring Range

NO.

Parameter Name

Measuring Range

1

Residual chlorine

0.05~5.00mg/L

51

Nickel

0.05~0.5mg/L

2

Total chlorine

0.05~5.00mg/L

52

Tin

0.01~0.50mg/L

3

Ozone

0.05~2.50mg/L

53

Acidity/phenolphthalein-D

10.0~1000mg/L

4

Nitrite-N

0.01~0.40mg/L

54

Carbonate-D

10.0~1500mg/L

5

Ammonia nitrogen

0.05~10.0mg/L

55

Bicarbonate-D

10.0~1500mg/L

6

Low turbidity 

0.5~60.0NTU

56

Selenium

0.10~1.00mg/L

7

Total phosphorus

0.01~1.00mg/L

57

Temperature-J

(-50~300)ºC

8

Hexavalent chromium

0.01~1.00mg/L

58

Salinity-J

(0.0~28)%

9

Sulfide

0.02~1.00mg/L

59

Potassium

30.0~100mg/L

10

COD

10~1000mg/L

60

Cadmium

0.10~5.0mg/L

11

Fluoride

0.02~2.00mg/L

61

Arsenic

0.006~0.5mg/L

12

Dissolved oxygen

0.1~10.0mg/L

62

Barium

1.0~10.0mg/L

13

Mn

0.05~5.00mg/L

63

Beryllium

0.01~0.30mg/L

14

Fe

0.10~3.00mg/L

64

TDS-J

0-9990ppm

15

Calcium-D

2~200mg/L

65

Molybdenum

0.01~0.30mg/L

16

Chlorine dioxide

0.10~3.00mg/L

66

Silver

0.05~1.00mg/L

17

Nitrate-N

0.5~20.0mg/L

67

Residual chlorine-1

0.5~10.0mg/L

18

High turbidity

5~400NTU

68

Total chlorine-1

0.5~10.0mg/L

19

Chroma

5~200PCU

69

Ozone-1

0.5~5.00mg/L

20

Total chromium

0.01~1.00mg/L

70

Ammonia nitrogen-1

1.0-50.0mg/L

21

Phosphate

0.1~1.0mg/L

71

COD-1

500~5000mg/L

22

 Sulfate

5.0~250.0mg/L

72

Total phosphorus-1 

0.5~10.0mg/L

23

CODmn-D

0.50~8.00mg/L

73

Total hardness

12.5~450mg/L

24

Total hardness-D

1.0~500.0mg/L

74

PH

5.5~9.5

25

Formaldehyde

0.05~1.50mg/L

75

Calcium

0.1~2.00mg/L

26

Volatile phenol

0.10~5.00mg/L

76

Manganese-1

0.5~10.00mg/L

27

PH-J

2.0~14.0

77

Copper-1

0.5~5.00mg/L

28

Chloride-D

20.0~500mg/L

78

Iron-1

0.5~10.00mg/L

29

Cyanide

0.03~1.00mg/L

79

Hexavalent chromium-1 

0.5~10.00mg/L

30

Aluminum

0.01~0.50mg/L

80

Total chrome

0.5~10.00mg/L

31

Cu

0.05~1.00mg/L

81

Aniline

0.03~50mg/L

32

Zn

0.05~3.00mg/L

82

Nitrobenzene

0.1~70mg/L

33

Free chlorine

0.05~5.00mg/L

83

Thiocyanate

0.15~1.5mg/L

34

Mg-D

2~200.0mg/L

84

Cobalt

0.01~0.50mg/L

35

Total alkalinity D

10.0~1000mg/L

85

Boron

0.20~8.00mg/L

36

Nitrates

5.0~150.0mg/L

86

Cyanide chloride

0.03~1.00mg/L

37

Nitrite

0.05~2.00mg/L

87

Plumbum

0.01~1.00mg/L

38

Orthophosphate

0.1~1.0mg/L

88

HG

2.00~40.0μg/L

39

Chlorite

0.05~2.0mg/L

89

Conductivity-J

0~1999us/cm

40

Sodium hypochlorite

100~5000mg/L

90

Iodine

0.00~2.00mg/L

41

Sodium chromate

0.01~1.00mg/L

91

Chloride

0.5~4.0mg/L

42

Peracetic acid

0.0~10.0mg/L

92

Vanadium

0.02~10.0mg/L

43

Hydrogen peroxide

1.0~100.0mg/L

93

Antimony

0.05~1.2mg/L

44

Hydrogen sulfide

0.01~1.00mg/L

94

Thorium

0.008~3.0mg/L

45

Silica 

1.0~20.0mg/L

95

Monomethyl hydrazine

0.02~0.8mg/L

46

Urea 

0.5~10.0mg/L

96

Triethylamine

0.5~3.5mg/L

47

Sulfite  

0.1~20.0mg/L

97

Trichloroacetaldehyde

0.10~2.00mg/L

48

Detergent

0.1~3.0mg/L

98

Diethylenetriamine

0.40~3.20mg/L

49

Hydrazine

0.01~0.10mg/L

99

Unsymmetrical  dimethylhydrazine

0.01~1.00mg/L

50  

Free ammonia  

0.1~5.0mg/L

Note: The suffix-J is a pen-type ion meter

 

Technical Parameters:

 

Model

BK-WQA

Light Source Life

≥ 100000h

Stability

≤ 0.005A / h

Detection System

Multi-channel independent detection system

Detection Circuit

High-precision constant test circuit

Display

Large touch screen display

Measurement Precision

≤ ± 5% or ± 10% F.S

Repeatability Precision

≤ ± 3%

Storage Capacity

Detection data 50000 group

Number of Curves

230

Printer

Built-in mini thermal line printer

Digestion Temp.

RT~ 500 ºC

Digestion Time

1 ~ 9999s

Processing Capacity

4 water samples 

Temp. Accuracy

<± 1 ºC

Temp. Uniform

<± 1 ºC

Interface

Standard RS232

Power Supply

AC110/220V±10%, 50/60Hz

Standard Accessory

4 holes digestion device

Optional Accessory

Kits for all parameters except the suffix-J, USB interface, Battery

External Size (W*D*H) mm

440*350*250

Package Size (W*D*H) mm

440*350*250

Net Weight (kg)

4

Gross Weight (kg)

5


Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab


Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab
Biobase China Fully Water Quality Analyzer BK-WQA-1 for Lab

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now