Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
After-sales Service: Yes
Application: Laboratory Apparatus
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (25)
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
  • Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Related Products
  • Exhibitions
  • After Sales Service
  • Contact
Overview

Basic Info.

Model NO.
BK-AA220AES
Warranty
> 1Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
/
Model
1150*930 *1450mm
Wavelength Range
170~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.6nm
Wavelength Accuracy
≤±0.1nm
Detector
Photomultiplier Tube Detector
Resolution
Spectral Bandwidth Deviation ≤0.02nm
Detection Limit
Flame Method for Cu: ≤0.002μg/Ml
Preciseness
Flame Method for Cu: ≤0.3%
Diffraction Grating
Groove 1800lines/mm, Blaze Wavelength 250nm
Lamp Stand
8
Power Supply
AC220V, 50Hz
External Size(W*D*H)
Main Unit: 1020*530*500mm
Package Size(W*D*H)
Main Unit: 1280*750*830mm
Net Weight
Main Unit: 85kg
Gross Weight
Main Unit: 160kg
Transport Package
Export Packing
Specification
1020*530*500mm
Trademark
BIOBASE
Origin
China
Production Capacity
500 PCS / Mout

Product Description

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer


 
Product Description

Atomic Absorption Spectrophotometer BK-AA220AES

 

Introduction:
BK-AA220AES flame graphite furnace integrated atomic absorption spectrophotometer, as an important precision instrument for metal analysis, has many advantages such as good selectivity, wide application range, high sensitivity, simple and fast operation, low analysis cost and high accuracy. It was widely used in industrial and livelihood fields such as geology, mining, metallurgy, agriculture, forestry, soil and fertilizer, hydrology and environmental protection, petrochemical industry, and third-party testing.



 

Features:

1. The flame and graphite furnace analysis device is fully automatic switching, convenient for time-saving, one click in place.

2. The flame system adopts high-reliability flow control and has automatic control such as automatic ignition.

3. Graphite furnace system built-in multiple temperature control protection system, using double air circuit breaker and other design methods, effectively preventing current overload or abnormal temperature rise.

4. Equipped with a reliable gas-liquid separation system, gas filter, and other accessories to ensure the working condition of the instrument when the ambient humidity is high and the gas source is limited.

5. Equipped with multiple safety interlocking devices and prompt information protection functions, the instrument has an automatic power outage, alarm prompts protection in case of abnormal situations involving safety.

6. The instrument features a modular design for easy customer replacement or repair.

7. The instrument supports functional extensions such as hydride method.


 

Product Parameters


 

Model

BK-AA220AES

Wavelength Range

170~900nm

Spectral Bandwidth

0.1, 0.2, 0.4, 1.6nm

Wavelength Accuracy

≤±0.1nm

Wavelength Repeatability

≤0.05nm

Detector

Photomultiplier tube detector

Baseline Stability

Drift ≤0.002Abs, noise ≤0.001Abs(Steady 30min)

Drift ≤0.002Abs, noise ≤0.001Abs(Dynamic 15min)

Resolution

Spectral bandwidth deviation ≤0.02nm

Manganese double line valley to peak energy ratio ≤25%

Characteristic Concentration/Content

Flame method for Cu: ≤0.025μg/mL/1%

Graphite furnace method for Cd: ≤0.5pg

Detection Limit

Flame method for Cu: ≤0.002μg/mL

Graphite furnace method for Cd: ≤0.4pg

Preciseness

Flame method for Cu: ≤0.3%

Graphite furnace method for Cd: ≤2.0%

Background Correction Ability

lamp calibration 1.0Abs, background ≥90 times

Self-absorption method correction 2.0Abs, background ≥90 times

Diffraction Grating

Groove 1800lines/mm, blaze wavelength 250nm

Lamp Stand

8(Support simultaneous preheating of 1~4 lights)

Standard Accessory

Element lamp(Cu*1, Cd*1, Hg*1), software working station

Optional Accessory

Wide slit combustion head, adjustable nebulizer, hydride vapor generator, audit trailing software, oil-free air compressor, recirculating cooling water system, computer, printer, autosampler, oxygen-enriched high-temperature flame

Power Supply

AC220V, 50Hz

External Size(W*D*H)

Main unit: 1020*530*500mm

GF power supply: 350*530*430mm

Package Size(W*D*H)

Main unit: 1280*750*830mm

GF power supply: 610*670*810mm

Net Weight

Main unit: 85kg

GF power supply: 32kg

Gross Weight

Main unit: 160kg

GF power supply: 70kg




Flame System

 

Air-acetylene Burner

100mm all-titanium burner

Atomization Chamber System

Integrally molded from polyphenylene sulfide

Burner System

Burner head height and horizontal position automatic adjustment, with burner angle rotatable

Gas Flow Control System

Automatic ignition/fame-out

Safety System

Emergency shutdown protection switch, automatic gas cut-off/shutdown/alarm in case of abnormal status, abnormal air pressure, ignition failure, gas leakage, abnormal flow rate, etc.



Graphite Furnace System

 

Temp. Control Mode

Optical and constant voltage

Heating Mode

Slope and stepped temperature programming

Temp. Range

RT~3000ºC

Heating Rate

≥3000ºC/s

Precision Error

≤1%

Graphite Tube Type

Straight, platform, concave type

Water&Gas Control Monitoring System

Inner gas, external gas and make up gas are controlled separately. Circulating water and gas flows monitoring system is equipped

Safety System

Graphite furnace cut-off high current protection switch, automatic pause/cooling/alarm in case of abnormal furnace state/water and gas circuit control failure/graphite tube problem/temperature control failure, etc.


 

Company Profile

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer


Packaging & Shipping

 

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer
Related Products

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer


 
Exhibitions

Exhibition

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer

 
After Sales Service

Our Services

 
Pre-sale service
  1. 24hours online to ensure quick response to customers' inquiry or online message;
  2. Guide customers to choose the best suitable machine model;
  3. Offer detailed specification and competitive prices;
Contract execution
  1. Machine production will be arranged strictly according to the contract;
  2. Machine photos will be sent to you for inspection during production;
  3. Update latest news after delivery and prepare customs clearance;
After-sale service
  1. Broken spare parts (except for wear parts) will be sent for free due to quality problems;
  2. In time response to customers technical problems;
  3. New products update for customers' reference.
Contact

 

Biobase Analysis Machine Atomic Absorption Spectrophotometer Aas Spectrophotometer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now
Product Groups
More