Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
---|---|
Type: | Patient Monitor |
Group: | Middle-aged and Old |
Transport Package: | Wooden |
Specification: | 879*660*764mm |
Trademark: | BIOBASE |
Customization: |
---|
Suppliers with verified business licenses
BIOBASE2000 Laboratory Medical Equipment Editable Sample Reagent Positions Automatic ELISA Processor
Technical parameters of BIOBASE2000 Laboratory Medical Equipment Editable Sample Reagent Positions Automatic ELISA Processor
Model |
BIOBASE2000 |
|
Sample pipetting unit |
Sample rack | 24 sample tubes/rack, at most 23 racks |
Primary sample tubes | 11.5-13mm | |
Pipetting | 8ul~1000ul, (10ul) CV<5% | |
Time to dispense | 12 minutes adding 96 samples | |
Dispensing system | 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station. |
|
Reagent pipetting unit |
Reagent racks | 2 reagent tanks(60ml)/ rack, at most 23 racks |
QC racks | 24 positions/QC rack, at most 23 racks | |
Pipetting | 8ul~1000ul,1ul stepping | |
pipetting precision | (100ul )CV≤0.5% | |
Time to dispense | 3 minutes(typical)^100ul of 96 reagents to plate from reagent bottle | |
Washing unit |
Programmable | Yes(options & parameters) |
Wash containers | 3 wash buffers at 2.0L,1 wash buffers at 5.0L,with level-sensing | |
Waste containers | 25L with waste full sensor | |
Washing system | two 8 nozzle manifolds, one to dispense and the other one to aspirate | |
Washing residual | <2μl | |
Reading unit |
Reading system | 8 independent photometric channels with mono and bichromatic reading capability |
Photometric range | 0.000 ~3.000 OD | |
Spectral range | 400-700nm | |
Optical filters | 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm) |
|
Reading inaccuracy | inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD | |
Incubation unit |
Incubators | 4 independent units |
Programmable | Yes | |
Temperature range | RT to 45 °C | |
Temperature accuracy | ±0.5ºC | |
Temperature staility | ±0.5ºC | |
Software unit |
Software system | Windows 7/8/107 or above, LIS system available |
Function application | work list set up, patient reports and result filing; calibration curve storage for each carried out test | |
Data reduction | cut-off (qualitative) | |
Others |
Power Supply | AC 110/220V±10%,50/60Hz,450W |
External Size(W*D*H) | 1235*710*880mm | |
PackageSize(W*D*H) | 1370*850*1439mm | |
Gross Weight | 220kg |
Features of BIOBASE2000 Laboratory Medical Equipment Editable Sample Reagent Positions Automatic ELISA Processor
4 microplates,2 pipetting probes
192 sample positions , 96 dilution positions,23 reagent positions, 16 common reagent positions,48 QC positions.
All sample & reagent positions can be editable.
Suppliers with verified business licenses