• Biobase China Toppette-Mechanical Pipette for Lab
  • Biobase China Toppette-Mechanical Pipette for Lab
  • Biobase China Toppette-Mechanical Pipette for Lab
  • Biobase China Toppette-Mechanical Pipette for Lab
  • Biobase China Toppette-Mechanical Pipette for Lab
  • Biobase China Toppette-Mechanical Pipette for Lab

Biobase China Toppette-Mechanical Pipette for Lab

After-sales Service: Online Technical Support
Warranty: 1 Year
Disposable: Non-Disposable
Power Source: Autoclavable
Material: Rubber / Plastic
Volume Range: 0.1-2.5μl
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Company Profile
  • Contact
Overview

Basic Info.

Model NO.
BK1000
Increment
0.05μl
Test Volume (μl)
2.5
Maximume Permissible Systematic Error
2.50%
Transport Package
Woodcase
Trademark
BIOBASE
Origin
China
Production Capacity
2000/Month

Product Description

Biobase China Toppette-Mechanical Pipette for Lab
MicroPette Plus Autoclavable Pipette

Product Description

 

Application:
All pipettes have been quality tested with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

 

    Features:


    Fully Autoclave:

    The MicroPette plus pipettes can be fully autoclaved at 121ºC, 1 atm for minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and dried over 12 hours.
    Biobase China Toppette-Mechanical Pipette for Lab

     

    Features for MicroPette plus:

    * Fully autoclavable

    * Light weight, ergonomic, low force design 

    * Digital display clearly reads volume setting

    * The pipettes cover volume range of 0.1μl to 10ml

    * Easy to calibrate and maintain 

    * Design helps avoid repetitive strain injuries

    * Manufactured from innovative materials
    Biobase China Toppette-Mechanical Pipette for Lab

    Technical parameter:
     

    Single-channel Adjustable Volume Pipettes

    Volume Range

    Increment

    Test Volume

    (μl)

    Maximume Permissible Systematic error

       (Inaccuracy)

    Maximume Permissible

    Random error

       (Inaccuracy)

     

     

     

    %

    μl

    %

    μl

    0.1-2.5μl

    0.05μl

    2.5

    2.50%

    0.0625

    2.00%

    0.05

    1.25

    3.00%

    0.0375

    3.00%

    0.0375

    0.25

    12.00%

    0.03

    6.00%

    0.015

    0.5-10μl

    0.1μl

    10

    1.00%

    0.1

    0.80%

    0.08

    5

    1.50%

    0.075

    1.50%

    0.075

    1

    2.50%

    0.025

    1.50%

    0.015

    2-20μl

    0.5μl

    20

    0.90%

    0.18

    0.40%

    0.08

    10

    1.20%

    0.12

    1.00%

    0.1

    2

    3.00%

    0.06

    2.00%

    0.04

    5-50μl

    0.5μl

    50

    0.60%

    0.3

    0.30%

    0.15

    25

    0.90%

    0.225

    0.60%

    0.15

    5

    2.00%

    0.1

    2.00%

    0.1

    10-100μl

    1μl

    100

    0.80%

    0.8

    0.15%

    0.15

    50

    1.00%

    0.5

    0.40%

    0.2

    10

    3.00%

    0.3

    1.50%

    0.15

    20-200μl

    1μl

    200

    0.60%

    1.2

    0.15%

    0.3

    100

    0.80%

    0.8

    0.30%

    0.3

    20

    3.00%

    0.6

    1.00%

    0.2

    50-200μl

    1μl

    200

    0.60%

    1.2

    0.15%

    0.3

    100

    0.80%

    0.8

    0.30%

    0.3

    50

    1.00%

    0.5

    0.40%

    0.2

    100-1000μl

    5μl

    1000

    0.60%

    6

    0.20%

    2

    500

    0.70%

    3.5

    0.25%

    1.25

    100

    2.00%

    2

    0.70%

    0.7

    200-1000μl

    5μl

    1000

    0.60%

    6

    0.20%

    2

    500

    0.70%

    3.5

    0.25%

    1.25

    200

    0.90%

    1.8

    0.30%

    0.6

    1000-5000μl

    50μl

    5000

    0.50%

    25

    0.15%

    7.5

    2500

    0.60%

    15

    0.30%

    7.5

    1000

    0.70%

    7

    0.30%

    3

     

    8-channel Adjustable Volume Pipettes

    Volume Range

    Increment

    Test Volume

    (μl)

    Maximume Permissible Systematic error

      (Inaccuracy)

    Maximume Permissible Random error

    (Inaccuracy)

     

     

     

    %

    μl

    %

    μl

    0.5-10μl

    0.1μl

    10

    1.50%

    0.15

    1.50%

    0.15

    5

    2.50%

    0.125

    2.50%

    0.125

    1

    4.00%

    0.04

    4.00%

    0.04

    5-50μl

    0.5μl

    50

    1.00%

    0.5

    0.50%

    0.25

    25

    1.50%

    0.375

    1.00%

    0.25

    5

    3.00%

    0.15

    2.00%

    0.1

    50-300μl

    5μl

    300

    0.70%

    2.1

    0.25%

    0.75

    150

    1.00%

    1.5

    0.50%

    0.75

    50

    1.50%

    0.75

    0.80%

    0.4

    12-channel Adjustable Volume Pipettes

    Volume Range

    Increment

    Test Volume

    (μl)

    Maximume Permissible Systematic error

       (Inaccuracy)

    Maximume Permissible Random error

    (Inaccuracy)

     

     

     

    %

    μl

    %

    μl

    0.5-10μl

    0.1μl

    10

    1.50%

    0.15

    1.50%

    0.15

    5

    2.50%

    0.125

    2.50%

    0.125

    1

    4.00%

    0.04

    4.00%

    0.04

    5-50μl

    0.5μl

    50

    1.00%

    0.5

    0.50%

    0.25

    25

    1.50%

    0.375

    1.00%

    0.25

    5

    3.00%

    0.15

    2.00%

    0.1

    50-300μl

    5μl

    300

    0.70%

    2.1

    0.25%

    0.75

    150

    1.00%

    1.5

    0.50%

    0.75

    50

    1.50%

    0.75

    0.80%

    0.4

    Fixed Volume Pipettes

    Volume Range

    Increment

    Test Volume

    (μl)

    Maximume Permissible Systematic error

       (Inaccuracy)

    Maximume Permissible Random error

    (Inaccuracy)

     

     

     

    %

    μl

    %

    μl

    5μl

    -

    5μl

    1.3%

    0.065

    1.2%

    0.06

    10μl

    -

    10μl

    0.8%

    0.08

    0.8%

    0.08

    20μl

    -

    20μl

    0.6%

    0.12

    0.5%

    0.1

    25μl

    -

    25μl

    0.5%

    0.125

    0.3%

    0.075

    50μl

    -

    50μl

    0.5%

    0.25

    0.3%

    0.15

    100μl

    -

    100μl

    0.5%

    0.5

    0.3%

    0.3

    200μl

    -

    200μl

    0.4%

    0.8

    0.2%

    0.4

    250μl

    --

    250μl

    0.4%

    1.0

    0.2%

    0.5

    500μl

    -

    500μl

    0.3%

    1.5

    0.2%

    1.0

    1000μl

    -

    1000μl

    0.3%

    3.0

    0.2%

    2.0

    2000μl

    -

    2000μl

    0.3%

    6.0

    0.15%

    3.0

    5000μl

    -

    5000μl

    0.3%

    15

    0.15%

    7.5

    Company Profile

     


    Founded in 1999, having over 2000 employees (till August, 2017), BIOBASE Group  is a new high-tech enterprise focusing on development, production and management of scientific equipment, In Vitro Diagnosis (IVD) instrument and reagent.

    BIOBASE Group is specialized in products of 8 areas including medical diagnosis, biosafety protection, disinfection and sterilization, water purification system, infant care products, cold chain products, software products, clean room project.

    Biobase China Toppette-Mechanical Pipette for Lab
     

    Contact

    Biobase China Toppette-Mechanical Pipette for Lab
     
     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Product Groups

    Diamond Member Since 2019

    Suppliers with verified business licenses

    Trading Company
    Number of Employees
    93
    Year of Establishment
    2012-06-01