• Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
  • Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
  • Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
  • Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
  • Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
  • Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer

Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer

Customized: Customized
Certification: /
Hood Size (W*D*H)mm: 980*630*740
Mattress Size(W*D)mm: 650*370
Thermostat Cover: Single-Layer
Access Port: 6(2 Iris Ports)
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Contact us
Overview

Basic Info.

Model NO.
BK-3201
Operating Window
4
Consumption
650W
Display
LED
Control Model
Air
Temp. Rise Time(From 25 ºC)
<30min
Temp. Fluctuation(ºC)
±0.5
Noise Level of Inside Incubator
<50dB[a]
Transport Package
Standard Package
Specification
Infant Radiant Warmer
Trademark
BIOBASE
Origin
Shandong, China (Mainland)
Production Capacity
100 Units/Month

Product Description

Biobase Neonate Baby Care Infant Incubator for hospital use
 

Product Description

Infant Radiant Warmer is one of the important equipment used in medical institutions. It is mainly used for constant temperature cultivation, temperature resuscitation, oxygen delivery, rescue, hospitalization and observation of sick infants and premature infants. It is used in hospitals, confinement centers, neonatology, etc.

Features:

LCD display

Double control modes of bed temperature and skin temperature

Double-layer thermostatic cover, automatic air curtain device

Humidity control function

Air & Oxygen blender

Oxygen supply system

Baby cot is infinitely adjustable

24 kinds of sound and light alarm, comprehensive protection of baby safety
Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer

Product Parameters

 

General parameters

Item

Specifications

Power supply

AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz(Optional)

Size(L*W*H)

950*645*(1250-11450) mm

Maximum heater output power(220VAC)

Air chamber heater:330W; Water tank heater:155W

Auxiliary network power output

AC220V/50Hz, both maximum permissible currents are 220V 1.5A

Heater indication

0~100%, 10% increasing amount

Temperature control mode

Bed temperature mode; skin temperature mode

Bed temperature control range

25.0~37.0ºC; 37.1~39.0ºC(Span mode)

Skin temperature control range

34.0~37.0ºC;37.1~38.0ºC(Span mode)

Skin temperature sensor display range

5.0~65.0ºC

Heating time

≤ 50min

Temperature variability

≤ 0.5ºC

Temperature uniformity (mattress in horizontal position)

≤ 0.8ºC

Temperature uniformity (mattress in tilted position)

≤1.0ºC

Difference between average incubator temperature and control temperature

≤1.5ºC

Skin temperature sensor accuracy

±0.3ºC

Humidity control

The running time of the tank after it is filled with distilled water

Humidity below 70%RH, at least 24h

Water tank capacity

1500ml

Humidity display range

0%RH~99%RH

Humidity control range

CAH%RH~90%RH(1% per adjustment)

Humidity control accuracy

±10%

Oxygen concentration control

Oxygen concentration display range

0%~99%

Oxygen concentration display resolution

1%

Oxygen concentration control accuracy

±5% oxygen volume concentration

Oxygen concentration setting range

21% ~ 60% (1% per adjustment)

Oxygen sensor service life

The maximum use time is 10000h at 100% oxygen concentration

Transport storage

Temperature

-20ºC~+55ºC

Atmospheric pressure range

500hPa~1060hPa

Relative humidity

≤93%RH

Packing size/ Gross Weight

Base packing size: 1200*800*870mm 50Kg

Body packing size: 1100*710*855mm 60Kg

The work environment

Relative humidity

30%RH~75%RH

Environment temperature

+20ºC~+30ºC

Pressure range

700hPa~1060hPa

Service altitude

≤2000m

Overvoltage category

 

Pollution level

2

Ambient air velocity

≤ 0.3 m/s

Other indicators

Ambient noise in the infant compartment of the incubator

No more than 55dB(A) at stable temperature

Carbon dioxide concentration in the infant compartment

A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after stabilization

The velocity of air flow over the baby mattress

≤0.35m/s

General

alarm

Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm

System alarm

Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure

 

 

Configuration:

Model

BK-3201(I)

BK-3201(II)

Temp. Control

Bed/Skin temperature

Bed/Skin temperature

Display

LCD

LCD

Bed Temp. Control Range

25ºC-39ºC

25ºC-39ºC

Skin Temp. Control Range

34ºC-38ºC

/

Humidity Control Range

CAH%~99%RH

CAH%~99%RH

Oxygen Control Range

21%-99%

/

Cabinet

Yes

Yes

 

Company Profile

Biobase Neonate Baby Care Infant Incubator Infant Radiant WarmerBiobase Neonate Baby Care Infant Incubator Infant Radiant WarmerBiobase Neonate Baby Care Infant Incubator Infant Radiant Warmer

Contact us


Biobase Neonate Baby Care Infant Incubator Infant Radiant Warmer
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now