Features:
1. The system offers a comprehensive and flexible isocratic mode, and also provides binary gradient and quaternary gradient systems. Detection capabilities include PDA, UV/VIS, FL, RI and ELS.
2. The new optional, solvent manager units can easily switch 4 to 8 kinds of solvent base on binary gradient system. There are several configurations available for user selection.
3. The real-time solvent pressure compensation control enhances detection precision. The integrated check valve ensures stable fluid delivery and simplifies maintenance.
Model |
BK-1800HPLC(Type I) |
BK-1800HPLC(Type II) |
BK-1800HPLC(Type III) |
BK-1800HPLC(Type IV) |
BK-1800HPLC(Type V) Quaternary Gradient Manual System with PDA |
Diode Array Detector |
/ |
/ |
Yes |
/ |
Yes |
High-pressure Constant Flow Pump |
EX1800 HPC*1 |
/ |
/ |
/ |
/ |
Binary High-Pressure Liquid Delivery Unit |
/ |
EX1800 BPC*1 |
EX1800 BPC*1 |
/ |
/ |
Quaternary High-Pressure Liquid Delivery Unit |
/ |
/ |
/ |
EX1800 QLPC*1 |
EX1800 QLPC*1 |
Solvent Tray |
EX1800 TR*1 |
EX1800 TR*1 |
EX1800 TR*1 |
EX1800 TR*1 |
EX1800 TR*1 |
UV Detector |
EX1800 UV*1 |
EX1800 UV*1 |
/ |
EX1800 UV*1 |
/ |
Manual Sampler 7725i |
Yes |
Yes |
Yes |
Yes |
Yes |
C18 5μm ID4.6*250mm |
Yes |
Yes |
Yes |
Yes |
Yes |
Workstation EX-Clarity C50 |
Yes |
Yes |
/ |
Yes |
/ |
Power Supply |
AC220/110V, 50/60Hz |
||||
Optional Accessory |
UV detector, Rl detector, PDA detector, ELS detector, FL detector, column, column oven, auto-sampler |
||||
Package Size(W*D*H) |
720*580*40 |
720*580*410mm*3 |
720*580*410mm*3 |
720*580*410mm*3 |
720*580*410mm*3 |
Gross Weight |
61kg |
65kg |
68kg |
57kg |
60kg |
EX1800 HPC High-Pressure Constant Flow Pump:
Liquid Infusion System |
Type I reciprocating infusion pumps |
Flow Rate Range |
62MPa 0.001~10ml/min, n0.001ml/min increments |
Max Output Pressure |
62MPa(corresponding 9000psi), 90MPa(corresponding 13000psi) |
Flow Accuracy |
≤0.06%RSD |
Flow Precision |
≤±0.3% |
Compression Compensation |
Automatic, continuous, selectable solvent type |
Post-column Cleaning |
Automatic post-column cleaning function, which can control the cleaning flow rate |
Extended Application |
Record the number of times the plunger rod seal is used |
EX1800 BPC Binary High-Pressure Liquid Delivery Unit:
Liquid Infusion System |
Type I reciprocating infusion pumps |
Flow Rate Range |
62MPa 0.001~10ml/min, n0.001ml/min increments |
Max Output Pressure |
62MPa(corresponding 9000psi), 90MPa(corresponding 13000psi) |
Flow Accuracy |
≤0.06%RSD |
Flow Precision |
≤±0.3% |
Compression Compensation |
Automatic, continuous, selectable solvent type |
Post-column Cleaning |
Automatic post-column cleaning function, which can control the cleaning flow rate |
Gradient Setting Range |
0~100% |
Extended Application |
Record the number of times the plunger rod seal is used |
EX1800 QLPC Quaternary High-Pressure Liquid Delivery Unit:
Liquid Infusion System |
Linear motor digital-driven pump |
Flow Rate Range |
Type I: 0.001~5.0ml/min in steps of 0.001 |
Max Output Pressure |
70MPa(corresponding 10150psi) |
Flow Accuracy |
≤0.06%RSD |
Flow Precision |
≤±0.3% |
Compression Compensation |
Automatic, continuous, selectable solvent type |
Post-column Cleaning |
Automatic post-column cleaning function, which can control the cleaning flow rate |
Gradient Setting Range |
0~100% |
Online Degassing |
Degassing channel systec AF |
Degassing Chamber |
480μl |
Extended Application |
Record the number of times the plunger rod seal is used |
EX1800 UV Detector:
Flow Cell Volume |
Volume 10.0μl; adopts cone structure/With optional temperature control module |
Light Source |
lamp+tungsten lamp |
Wavelength Range |
190~900nm |
Spectrum Bandwidth |
8nm |
Wavelength Accuracy |
±1nm |
Wavelength Precision |
Below 0.1nm |
Noise |
≤0.25*10AU(static)/±1*10AU(dynamic, under specified test conditions) |
Drift |
≤0.4*10^-4AU/h(static)/±2*10^-4AU/h(dynamic, under specified test conditions) |
Sampling Frequency |
Up to 100Hz |
EX1800 PDA Detector:
Number of Diode Arrays |
1024 |
Light Source |
lamp+tungsten lamp |
Wavelength Range |
200~800nm |
Wavelength Precision |
±0.5nm |
Wavelength Accuracy |
±1nm |
Noise |
±5*10^6AU, under specified conditions |
Drift |
1*10^-4AU/h, under specified conditions |
Sampling Frequency |
Up to 100Hz |
Spectral Bandwidth |
10nm |
Flow Cell Path Length |
5mm(10mm is optional) |