Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave

Product Details
Customization: Available
Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Still deciding? Get samples of US$ 1270/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (25)
  • Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
  • Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
  • Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
  • Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
  • Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Related Products
  • Packaging & Shipping
  • FAQ
  • Our Advantages
  • Contact Us
Overview

Basic Info.

Model NO.
BKQ-B50II
Certification
/
Electric Tension
220V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Capacity
50L
Chamber Size(mm)
386*514
Chamber Material
SUS304
Designed Pressure
0.28MPa
Designed Temp
150c
Working Pressure
0.22MPa
Working Temp
105~136c
Timing Range
0~999min
Dynamic Pulse Exhaust Times
0~9 Times
Gross Weight
102kg
External Size(W*D*H)mm
640*550*1070
Packing Size(W*D*H)mm
750*745*1240
Ss Basket
2PCS
Power Supply
AC110/220V±10%, 50/60Hz
Consumption
4.7kw
Transport Package
International Standard
Specification
Autoclave
Trademark
BIOBASE
Origin
China
Production Capacity
100 Units/Month

Product Description


Biobase BKQ-B50II CE Certified Class B Laboratory Vertical Autoclave
 
Product Description

 

Range of application:

There are 5 fixed programs and 2 DIY programs according to different sterilization objects 
such as dressings, equipment, tools, rubber, liquid, culture medium, waste, etc.

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
Product Parameters

 

2. Parameters of Autoclave:

Model

BKQ-B50II

BKQ-B75II

BKQ-B100II

BKQ-B12BII

BKQ-B150II

BKQ-B200II

Capacity

50L

75L

100L

120L

150L

200L

Chamber Size(mm)

φ386*514

φ386*694

φ386*874

φ386*1054

φ500*760

φ500*1000

Chamber Material

SUS304

Designed Pressure

0.28Mpa

0.24Mpa

Designed Temp

150ºC

138ºC

Working Pressure

0.22MPa

0.217MPa

Working temp.

105~136ºC

50~134ºC

Temp. Displayaccuracy

±0.1ºC

Timing range

0~999min

0~99h

Dynamic Pulse 

Exhaust Times

0~9 times

Dynamic Pulse 

Exhaust Temp.

105~134ºC

Dissolution Temp. 

Range

60~100ºC(programmable)

Temp. Holding Range

40~60ºC(programmable)

Consumption

4.4KW

4.7KW

5.2KW

5.2KW

6KW

Power Supply

AC110/220V±10%, 50/60Hz

380V, 50Hz/200V, 50/60Hz

SS Basket

1 pc

2pcs

2pcs

3pcs

3 pcs

4pcs

External Size(W*D*H)mm

640*550*970

640*550*1070

640*550*1270

640*550*1370

650*650*1400

650*650*1700

Packing Size(W*D*H)mm

750*745*1100

750*745*1240

750*745*1450

750*745*1540

800*760*1500

800*760*1690

Gross Weight(kg)

102

112

125

140

190

200

Note: It is applicable to the altitude below 3,500m

3. Features of Autoclave:

Safety Features:

1. Over pressure. Safety valve can automatically open to release pressure.

2. Over temperature. The system will power off automatically.

3. Door sensor. Sensor at door closing position, to check the door status. If door is open, operation will stop.

4. Anti-dry out function. If water level is too low, system will power off and error code displays on screen.

5. Over current. over voltage or electric leakage protection apparatus-air switch.

6. Door cover.The door is covered with safety shell made of thermal insulation material, which can protect operator from burning by heat and looks nice.

Technical Features:

* Water inlet filter to keep high water quality(except BKQ-B150/200II).

* Optional printer for recording sterilization data.

* LED screen displays all steps of full process as well as error codes.

* Independent quick service window, easy for repairing and maintenance.

* Automatic selecting quick or low exhaust to avoid sterilization liquid overflowing.

* Sterilization programs for dressings, equipment, rubber, culture medium, waste, etc.

* Hand wheel type of quick-open door structure, self-expandable sealing ring, easy operating and safe.

* Complete process of filling water, dynamic pulse exhaust, heating, sterilizing, draining and drying runs automatically.

* Adopting certain temperature(98~102ºC) exhaust method and dynamic pulse exhaust method to empty the cold air inside chamber for ensuring steam saturability.

* Inner stainless steel water tank for water and steam to circulate inside. Steam dose not exhaust during sterilization,
  so as to keep the outside clean and dry(except BKQ-B150/200II).

* Drying function (except BKQ-B150/200II)

Company Profile

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave
Related Products

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave

 
Packaging & Shipping

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave



 
FAQ

 



1. How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
2. How about Biobase delivery time?
Within 7-15 workdays after receiving deposit.
3. How about Biobase validity of quotation?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
4. What's the shipping port?
FOB to Qingdao Port, China(also can ship according to customers' request)
5. How about the package?
Bubble film & cotton & standard export wooden case
6. How to inspect the goods?
Products will be checked by our QC staff first, then our project manager.
Client can come and check by themselves or by third party check is available.
Our Advantages

Biobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical AutoclaveBiobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave


Contact Us

(Sales Representative)

If you have any needs, please do not hesitate to contact me! 
Biobase Bkq-B75II Class B Laboratory Sterillization Vertical Autoclave

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More