• Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
  • Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
  • Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
  • Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
  • Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
  • Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f

Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f

After-sales Service: 24 Hour′s Online Support
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Resolution
Principle: Classic Spectrometer
Samples:
US$ 1300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Promotion
  • Company Profile
  • FAQ
  • Contact Us
Overview

Basic Info.

Model NO.
BK-AA4530F
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Non-Customized
Wavelength Accuracy
0.15nm
Wavelength Repeatability
0.04nm
Grating
1800 Lines/mm
Lamp Stand
8
Power Supply
220V, 50/60Hz
Gross Weight(Kg)
205
Wavelength Range
190~900nm
Transport Package
International Standard
Specification
Atomic Absorption Spectrophotometer
Trademark
BIOBASE
Origin
China
HS Code
9027300000
Production Capacity
100 Units/Month

Product Description



 
BK-AA4530F Atomic Absorption Spectrophotometer
 
Product Description



 

Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f

* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

* Integrated floated optical platform design improves the optical system shock resistance stable. 

* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

* Position adjusting: the flame burner can be set on the best position automatically.

* Fully automated wavelength scanning and peak searching.

* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

* lamp and self-absorption background calibration.

* Measuring method: flame absorption method and emission method.

* Result printing: parameter, data result and diagram.

* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

 

 

 


Pictures of Atomic Absorption Spectrophotometer

Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f



Specificateion of Atomic Absorption Spectrophotometer
Product Parameters

 

Model

BK-AA4530F

Wavelength Range

190~900nm

Wavelength Accuracy

±0.15nm

Wavelength Receptivity

≤0.04nm

Base Line Stability

≤0.002A/30min (Cu)

Characteristic Concentration 

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Measurement Repeatability

≤0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Efficient glass atomizer

Lamp stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50/60Hz

Packing Size(mm)

850*700*750(Main instrument)

950*620*1020(Accessories )

Gross Weight(kg)

105Kg  (Main instrument)

100Kg   ( Accessories )

Standard Accessories

PC workstation

HP inkjet printer 

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Air filter

Optional Accessories

Graphite Furnace

Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

 

 

FLAME SYSTEM

Acetylene Air Burner

100mm

Ignition Dynamic Baseline Drift

≤0.006A/30min

Characteristic Concentration

≤0.025μg/ml/1%(Cu)

Related Standard Deviation of the Accuracy

 

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety System

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

 

GRAPHITE FURNACE(Optional):

Max. Temperature

3000ºC

Max Heating Speed

≥2000ºC/S

Characteristic Quantity

Cd≤0.5*10-12g  Cu≤0.5*10-11g

Accuracy

Cu≤3% Cd≤3%

Safety System

Over current protection Low air pressure alarm / protection

Low cooling water flow alarm/protection

Power Supply

220V, 50Hz

Consumption

7000W

Packing Size(mm)

550*450*300

Gross Weight(kg)

65

Promotion
 

Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530fBiobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f

Company Profile

 


Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
 
FAQ

 


1. How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
2. How about Biobase delivery time?
Within 7-15 workdays after receiving deposit.
3. How about Biobase validity of quotation?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
4. What's the shipping port?
FOB to Qingdao Port, China(also can ship according to customers' request)
5. How about the package?
Bubble film & cotton & standard export wooden case
6. How to inspect the goods?
Products will be checked by our QC staff first, then our project manager.
Client can come and check by themselves or by third party check is available.


 
Contact Us

 


Biobase China Aas Atomic Absorption Spectrophotometer with 8 Lamp Stand Bk-AA4530f
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now