• Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
  • Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
  • Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
  • Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
  • Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
  • Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Capacity: One Person
After-sales Service Provided: Engineers available to service machinery overseas
Certification: CE
Usage: Research Institute
Noise: >62DB
Type: Horizontal Flow Clean Bench
Samples:
US$ 2700/Box 1 Box(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Technical Parameters
  • Company Profile
  • After Sales Service&Exhibition
  • Customer feedback
  • Packaging & Shipping
  • Contact Gloria
Overview

Basic Info.

Model NO.
BSC-1100IIB2-Pro
External Size(W*D*H)
1100*750*2250 mm
Internal Size(W*D*H)
940*600*660mm
Tested Opening
Safety Height 200 mm, Safety Height 200mm (8′′)
Control System
Microprocessor
Airflow System
0% Air Recirculation, 100% Air Exh
Material
Steel
ULPA Filter
Two, 99.995% Efficiency at 0.12μm, Fi
Transport Package
International Standard Export Package
Specification
240kg
Trademark
BIOBASE
Origin
China
Production Capacity
100unit/Month

Product Description


Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory
Product Description

BIOBASE China Class II B2 Biological Safety Cabinet

100% Air Exhaust Cabinet
Three protection: operator, sample and environment.Airflow system: 0 % air recirculation, 100% air exhaust
A Class II B2 BSC, also called a total exhaust cabinet, is necessary when significant amounts of radionuclides and volatile
chemicals are expected to be used.Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Advantages:

1. Time reserve function.

2. Motorized front window.

3. HEPA filter life and UV life indicator.

4. Automatic air speed adjustable with filter block.

5. With memory function in case of power-failure.

6. Work area surrounded by negative pressure, it can ensure maximum safety in work area.

7. Most accessories are standard, which saves your money. There is no need to pay more.

8. Audio and visual alarm (filter replacement, window over height, abnormal air flow velocity, etc).

9. Remote control. All functions can be realized with it, making the operation much easier and more convenient.

10. Interlock function: UV lamp and front window; UV lamp and blower, fluorescent lamp; blower and front window.

11. Foot switch. Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement.

Technical Parameters
 
Model BSC-1100IIB2-PRO BSC-1500IIB2-PRO BSC-1800IIB2-PRO
External Size(W*D*H) 1100*750*2250 mm 1500*840*2275mm 1800*840*2275 mm
Internal Size(W*D*H) 940*600*660mm 1300*670*630mm 1600*670*630mm
Tested Opening Safety Height 200 mm(8")
Max Opening 420mm(17") 500mm(20") 480mm(20")
Inflow Velocity 0.53±0.025 m/s
Down flow Velocity 0.33±0.025 m/s
ULPA Filter Two, 99.9995% efficiency at 0.12 μm,filter life indicator.
Front Window Motorized,two-layer laminated toughened glass ≥ 6mm,anti UV.
Noise ≤ 67 dB
UV Lamp 30W*1 40W* 1 40W*1
UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination.
Illuminating Lamp LED Lamp
12W*2 16W*2 16W*2
Illumination ≥1000Lux
Consumption 1050W 1270W 1800W
Waterproof Sockets Two, total load of two sockets: 500W
Display 7 inch touch screen display: exhaust filter and downflow filter pressure, filter and UV lamp working time,inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 0% air recirculation, 100% air exhaust
Alarm Abnormal airflow velocity; Filter replacement; Front window at unsafe height.
Exhaust Duct 4 meters PVC duct, Diameter:300mm
Material Work Zone: 304 stainless steel
Main Body: Cold-rolled steel with anti-bacteria powder coating.
Work Surface Height 750mm
Caster Foot master caster
Power Supply AC 220V±10%, 50/60Hz; 110V±10%, 60Hz (110V/60Hz is not applicable to BSC-1800IIB2-Pro)
Standard Accessory Illuminating lamp, UV lamp*2,base stand, remote control, foot switch, exhaust blower,
exhaust duct, drain valve, waterproof sockets*2, pipe strap*2
Optional Accessory Water and gas tap, Electric height adjustable base stand
Gross Weight 265kg;50kg 325kg;56kg 420kg;60kg
Package Main Body 1250* 990* 1770 mm 1650*990*1820 mm 2000*1075*1910 mm
Exhaust Blower (W*D*H) 930* 800* 690 mm 930* 800* 710 mm 920* 710* 680
Company Profile

Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

After Sales Service&Exhibition


Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for LaboratoryBiobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for LaboratoryBiobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for LaboratoryBiobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Customer feedback


Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for LaboratoryBiobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Packaging & Shipping


Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Contact Gloria


Biobase Biosafety Cabinet Class II B2 Biological Safety Cabinet for Laboratory

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now