• Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
  • Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
  • Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
  • Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
  • Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
  • Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

After-sales Service: Yes
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: New Spectrometer
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Mainly Products
  • Company Profile
  • BIOBASE Exhibitions
  • Show Room
  • Contact
Overview

Basic Info.

Model NO.
BK-AA4530F
Wavelengths
Infrared Spectrometer
Dispersive Element
Interferometer Spectrometer
Light Number
Monochromator
Certification
CE
Customized
Customized
Model
Bk-AA4530f
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4,1.0 and 2.0nm
Wavelength Accuracy
≤±0.15nm
Wavelength Repeatability
≤0.04nm
Base Line Stability
≤0.002A/30min (Cu)
Characteristic Concentration
0.02μg/Ml/1% (Cu)
Detection Limit
0.004μg/Ml (Cu)
Preciseness
≤0.5%
Grating
1800 Lines/mm
Inflamer
All-Metal Titanium Burner
Atomizer
Effective Glass Atomizer
Lamp Stand
8
Power Supply
220V, 50Hz
Acetylene Air Burner
100mm
Transport Package
Wooden Case or Carton Package
Specification
1138*733*1028
Trademark
BIOBASE
Origin
China
Production Capacity
1000 Unit/Units Per Year

Product Description

Atomic Absorption Spectrophotometer

Product Description

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for LabBiobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

Features:

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

Integrated floated optical platform design improves the optical system shock resistance stable.

Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

Position adjusting: the flame burner can be set on the best position automatically.

Fully automated wavelength scanning and peak searching.

Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

Measuring method: flame absorption method and emission method.

Result printing: parameter, data result and diagram.

Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

Product Parameters

Model

BK-AA4530F

Wavelength Range

190~900nm

Spectral Bandwidth

0.1, 0.2, 0.4,1.0 and 2.0nm

Wavelength Accuracy

≤±0.15nm

Wavelength Repeatability

0.04nm

Base Line Stability

0.002A/30min (Cu)

Characteristic Concentration

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Preciseness

0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Effective glass atomizer

Lamp Stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50Hz

Packing Size(W*D*H) mm

860*705*755 (Main instrument); 545*445*1385 (Accessories)

Gross Weight(kg)

105 (Main instrument); 100 (Accessories)

Standard Accessories

Software; Inkjet printer; Oil free Air compressor;

Acetylene reducing valve; Cu Hollow cathode lamp; Air filter

Optional Accessories

Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler

Flame System:

Acetylene Air Burner

100mm

Ignition Dynamic Baseline Drift

0.006A/30min

Characteristic Concentration

0.025μg/ml/1%(Cu)

Related Standard Deviation of the Accuracy

0.5%(Cu, absorbance>0.8A) (detection limit Cu0.008μg/ml)

Safety System

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite Furnace(Optional):

Max. Temperature

3000°C

Max Heating Speed

≥2000°C/S

Characteristic Quantity

Cd0.5*10T2g Cu0.5*1011g

Accuracy

Cu3% Cd3%

Safety System

Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection

Power Supply

220V, 50Hz

Consumption

7000W

Packing Size(W*D*H) mm

740*640*700

Gross Weight(kg)

90

 

 

Mainly Products

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab
 

Company Profile

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

BIOBASE Exhibitions

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

Show Room

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab

Contact

 

Biobase Graphite Furnace Atomizer Atomic Absorption Spectrophotometer for Lab


 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now