• Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
  • Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
  • Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
  • Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
  • Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
  • Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

After-sales Service: One Year Warranty and Lifetime Online Support
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Related Products
  • Company Profile
  • Packaging & Shipping
  • After Sales Service
  • Exhibition
  • Contact us
Overview

Basic Info.

Model NO.
BK-D580
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
\
Certification
ISO9001, CE
Customized
Non-Customized
Optical System
Double Beam, Grating 1200 Lines/mm
Wavelength Range
190~1100nm
Spectral Range
1nm
Wavelength Accuracy
± 0.3nm
Wavelength Repeatability
≤ 0.2nm
Stray Light
≤ 0.05 T @ 360nm; 220nm
Stability
± 0.0008A / H @ 500nm
Baseline Flatness
± 0.0005A
Noise
± 0.0002ABS
Display
65 Thousand True Color 7 Inch TFT LCD(480 *800)
Photometric Mode
T, a, C, E
Photometric Range
0~200% T,-0.301~3.0A
Detector
Silicon Photodiode
Light Source
Lamp, Tungsten Lamp
Transport Package
International Standard
Specification
Spectrophotometer
Trademark
BIOBASE
Origin
China
Production Capacity
100 Units/Month

Product Description

Product Description

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer 


Features of Spectrophotometer:

1 With GLP self-check function, check the wavelength accuracy and Photometry accuracy
2 Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
3 With Si02 coating optical mirror, reducing the pollution from outside fully
4 PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test for PC Series


 

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer




Basic Functions:

1, Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2, Quantitative
Linear fit and Linear fit through zero two modes
 a. Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve            
 b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings
 c. Can save 240 group curves, can test 240 data in each curve
 d. Double wavelength, Triple wavelength test functions
3, Kinetics
Used for time course scanning or reaction ratecalculations△A/t,can search all data.  
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most 

Product Parameters

 

Model

BK-D560

BK-D580

BK-D590

Optical System

Double Beam, Grating 1200 lines/mm

Wavelength Range

190~1100nm

Spectral Range

1.8nm

1nm

0.5,1,2,4,5nm

Wavelength Accuracy

± 0.3nm

Wavelength Repeatability

≤ 0.2nm

Photometric Accuracy

± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.3% T (0~100% T)  

Photometric Repeatability

0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T)

Stray Light

≤ 0.05 T @ 360nm; 220nm

Stability

± 0.0008A / h @ 500nm

Baseline Flatness

± 0.0005A

Noise

± 0.0002Abs

Display

65 thousand true color 7 inch TFT LCD(480 *800)

Photometric Mode

T, A, C, E

Photometric Range

0~200% T,-0.301~3.0A

Detector

Silicon Photodiode

Light Source

Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

USB  Print and data output, Connect PC

Standard Accessories

10mm glass cuvette *4 units  10mm quartz cuvette *2 units,software

Optional Accessories

Single cell holder,General cell holder,Test tube holder,Solid sample holder, lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system

 

Power Supply

AC110V/220±10%, 60/50Hz

Packing Size(mm)

740*570*440

Gross Weight(kg)

25

Related Products

 
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

 

Company Profile

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer
Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis SpectrophotometerBiobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

Packaging & Shipping

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

After Sales Service

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

Exhibition

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

Contact us

Biobase DNA/Protein Analysis 190 to 1100nm Double Beam Scanning UV/Vis Spectrophotometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now