Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • After Sales Service
  • FAQ
  • Contact me
Overview

Basic Info.

Model NO.
BK-FP3536
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Thermometer
-6 Degrees~400degrees
Ambient Temperature
-10 Degrees~50degrees
Consumption
650W
Test Flame Applicator
It Applies The Test Flame Automatically
Dimension (W*D*H)
Dimension (W*D*H)
Packing Size (W*D*H)
520*440*340mm
Gross Weight
12kg
Transport Package
Export Packing
Specification
BK-FP3536
Trademark
BIOBASE
Origin
China
Production Capacity
1000 PCS / Mout

Product Description

Product Description

Product Description

BIOBASE Open-Cup Flash Point Tester

Biobase China Open-Cup Flash Point Tester Bk-Fp3536 for Lab

Product Features

* It adopts special heating furnace to ensure the safety of test.

* The instrument adopts desktop structure. Easy to operate.

* Stainless steel working table and furnace. 

* BK-FP3536A  Automatic Open-Cup Flash Point Tester

* LCD screen to display.

* Automatically open the lid,detect the flash point and print test data.The test arm automatically rise up and lower down.

Product Parameters

Specification

Model
BK-FP3536
BK-FP3536A
Thermometer
-6ºC~400ºC. It is the same as thermometer ASTM 11C
Ambient Temperature
-10ºC~50ºC
10ºC~40ºC
Relative Humidity
≤85%
Consumption
650W
400W
Test Flame Applicator
It applies the test flame automatically
Heating Device
Quartz tube furnace heating, no naked fire, explosion prevented
The power is adjustable from 0W to 600W
Igniting Device
(1) Ignition source: coal gas(or civil gas)
(2) Flame diameter is 3.2mm~4.8mm
Electric ignition
Gas flame diameter is 3.2mm~4.8mm


Flash Point Determination
 
Range: Ambient to 400ºC
Repeatability: ≤8ºC
Reproducibility: ≤17ºC
Accuracy: 0.1ºC
Power Supply
AC220V±10%, 50Hz
Dimension (W*D*H)
350*290*350mm
410*360*310mm
Packing Size (W*D*H)
520*440*340mm
600*510*600mm
Gross Weight
12kg
25kg
Company Profile

Company Profile
Biobase China Open-Cup Flash Point Tester Bk-Fp3536 for LabBiobase China Open-Cup Flash Point Tester Bk-Fp3536 for Lab

      Packaging & Shipping

       

      Biobase China Open-Cup Flash Point Tester Bk-Fp3536 for Lab
       
      After Sales Service

      After-sales Service

      Pre-sale service

      1. 24hours online to ensure quick response to customers' inquiry or online message;
      2. Guide customers to choose the best suitable machine model;
      3. Offer detailed specification and competitive prices;
      Contract execution
      1. Machine production will be arranged strictly according to the contract;
      2. Machine photos will be sent to you for inspection during production;
      3. Update latest news after delivery and prepare customs clearance;
      After-sale service
      1. Broken spare parts (except for wear parts) will be sent for free due to quality problems;
      2. In time response to customers technical problems;
      3. New products update for customers' reference.
       
      Biobase China Open-Cup Flash Point Tester Bk-Fp3536 for Lab
      FAQ

      FAQ

      1.Why choose BIOBASE?
      We are the leading manufactuer of biochemistry analyzer and reagent, OEM & ODM service are offered. And we have our own overseas techinican and installation team.
      2.How about the sample of Biobase product?
      We could send you the samples but the freight and the sample are charged.
      3.How about Biobase payment term? 
      T/T & L/C &Western Union(40% deposit, the balance before shipment)
      4.How about BIOBASE delivery time?
      Within 3-15 workdays after receiving deposit.
      5.How about BIOBASE validity of quotation ?
      Usually 30 days as the shipping freight and exchange rate can be fluctuant.
      6.What is the shipping port?
      FOB to Qingdao Port,China(also can ship according to customers' request)
      7.How about the package? 
      Bubble film + Cotton +Standard export wooden case for equipments. Bubble film + Cotton + Biological ice pack
      8.How to inspect the goods? 
      Products will be checked by our QC staff frist, then our proejct manager. Client can come and check bythemselves or third party check is available.

       
      Contact me

      CONTACT ME

       
      Biobase China Open-Cup Flash Point Tester Bk-Fp3536 for Lab
       
       



       
       
         
         

        Send your message to this supplier

        *From:
        *To:
        *Message:

        Enter between 20 to 4,000 characters.

        This is not what you are looking for? Post a Sourcing Request Now