• Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
  • Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
  • Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
  • Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
  • Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
  • Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: CE
Electric Tension: 220V
LCD Display: Without LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Samples:
US$ 1700/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Technical Parameters
  • Company Profile
  • Packaging & Shipping
  • After Sales Service
  • Our Advantages
  • Contact Gloria
Overview

Basic Info.

Model NO.
BKQ-B75II
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Capacity
75L
Chamber Size(mm)
386*694
Transport Package
Internationa Standard Wooden Package
Specification
750*745*1240
Trademark
BIOBASE
Origin
China
Production Capacity
10 Units Per Month

Product Description

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave
Product Description

BIOBASE Vertical Autoclave

Application range: 

There are 5 fixed programs and 2 DIY programs according to different sterilization objects such as dressings, equipment, tools, rubber, liquid, culture medium, waste, etc.

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Safety Features:

  * Over pressure. Safety valve can automatically open to release pressure.

  * Over temperature. The system will power off automatically.

  * Door sensor. Sensor at door closing position, to check the door status. If door is open, operation will stop.

  * Anti-dry out function. If water level is too low, system will power off and error code displays on screen.

  * Over current. Over voltage or electric leakage protection apparatus-air switch.

  * Door cover. The door is covered with safety shell made of thermal insulation material, which can protect operator from burning by heat and looks nice.

 

Technical Features:

 * Water inlet filter to keep high water quality(except BKQ-B150/200II).

 * Optional printer for recording sterilization data.

 * LED screen displays all steps of full process as well as error codes.

 * Independent quick service window, easy for repairing and maintenance.

 * Automatic selecting quick or low exhaust to avoid sterilization liquid overflowing.

 * Sterilization programs for dressings, equipment, rubber, culture medium, waste, etc.

 * Hand wheel type of quick-open door structure, self-expandable sealing ring, easy operating and safe.

 * Complete process of filling water, dynamic pulse exhaust, heating, sterilizing, draining and drying runs automatically.

 * Adopting certain temperature(98~102ºC) exhaust method and dynamic pulse exhaust method to empty the cold air inside chamber for ensuring steam saturability.

 * Inner stainless steel water tank for water and steam to circulate inside. Steam dose not exhaust during sterilization, so as to keep the outside clean and dry(except BKQ-B150/200II).

 * Drying function (except BKQ-B150/200II)

 * Optional stainless steel bucket and tray(except BKQ-B150/200II).

 * Standard 1 pc stainless steel tray(except BKQ-B150/200II).

Technical Parameters

Model

BKQ-B50II

BKQ-B75II

BKQ-B100II

BKQ-B120BII

BKQ-B150II

BKQ-B200II

Capacity

50L

75L

100L

120L

150L

200L

Chamber Size(mm)

φ386*514

φ386*694

φ386*874

φ386*1054

φ500*760

φ500*1000

Chamber Material

SUS304

Designed Pressure

0.28Mpa

0.24Mpa

Designed Temp

150ºC

138ºC

Working Pressure

0.22MPa

0.217MPa

Working Temp.

105~136ºC

50~134ºC

Temp. Display Accuracy

±0.1ºC

Timing Range

0~999min

0~99h

Dynamic Pulse 

Exhaust Times

0~9 times

Dynamic Pulse 

Exhaust Temp.

105~134ºC

Temp. Holding Range

45~60ºC

Consumption

4.4KW

4.7KW

5.2KW

5.2KW

6KW

Power Supply

AC110/220V±10%, 50/60Hz

380V, 50Hz/200V, 50/60Hz

SS Basket

1 pc

2pcs

2pcs

3pcs

3 pcs

4pcs

External Size(W*D*H)mm

640*550*970

640*550*1070

640*550*1270

640*550*1370

650*650*1400

650*650*1700

Package Size(W*D*H)mm

750*745*1100

750*745*1240

750*745*1450

750*745*1540

800*760*1530

800*760*1720

Gross Weight(kg)

102

112

125

140

213

238

Note: It is applicable to the altitude below 3,500m

Company Profile

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Packaging & Shipping

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

After Sales Service

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab AutoclaveBiobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Our Advantages


Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Contact Gloria

Biobase China Vertical Autoclave Steam Sterilizer Use for Lab Autoclave

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now