Certification: CE, /
Scale: Large
Type: Infant Incubator
Power Supply Requirement: AC220V/50Hz, 1320va
Size(L*W*H): 950*645*(1320-1520) mm
Skin Temperature Sensor Display Range: 5.0-65.0
Samples:
US$ 1965/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (25)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • FAQ
  • Contact Us
Overview

Basic Info.

Model NO.
BK-3201Type II
Heating Time
≤ 30min
Temperature Variability
≤ 0.5ºC
Temperature Uniformity
≤ 0.8ºC
Packing Size
Base Packing Size: 1200*850*920mm Body Packing Siz
Relative Humidity
30%Rh-75%Rh
Environment Temperature
+20ºC-+30ºC
Pressure Range
800hpa-1060hpa
Transport Package
International Standard
Specification
Baby Radiation Warming
Trademark
BIOBASE
Origin
China
Production Capacity
100 Units/Month

Product Description

Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II
Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer BK-3201
Product Description

 


Product Overview:

1. Pictures
Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II
Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II
 
Product Parameters

2. Parameters 

ral parameters
Item
Specifications
Power supply
AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz(Optional)
Size(L*W*H)
950*645*(1250-11450) mm
Maximum heater output power(220VAC)
Air chamber heater:330W; Water tank heater:155W
Auxiliary network power output
AC220V/50Hz, both maximum permissible currents are 220V 1.5A
Heater indication
0~100%, 10% increasing amount
Temperature control mode
Bed temperature mode; skin temperature mode
Bed temperature control range
25.0~37.0ºC; 37.1~39.0ºC(Span mode)
Skin temperature control range
34.0~37.0ºC;37.1~38.0ºC(Span mode)
Skin temperature sensor display range
5.0~65.0ºC
Heating time
≤ 50min
Temperature variability
≤ 0.5ºC
Temperature uniformity (mattress in horizontal position)
≤ 0.8ºC
Temperature uniformity (mattress in tilted position)
≤1.0ºC
Difference between average incubator temperature and control temperature
≤1.5ºC
Skin temperature sensor accuracy
±0.3ºC
Humidity control
The running time of the tank after it is filled with distilled water
Humidity below 70%RH, at least 24h
Water tank capacity
1500ml
Humidity display range
0%RH~99%RH
Humidity control range
CAH%RH~90%RH(1% per adjustment)
Humidity control accuracy
±10%
Oxygen concentration control
Oxygen concentration display range
0%~99%
Oxygen concentration display resolution
1%
Oxygen concentration control accuracy
±5% oxygen volume concentration
Oxygen concentration setting range
21% ~ 60% (1% per adjustment)
Oxygen sensor service life
The maximum use time is 10000h at 100% oxygen concentration
Transport storage
Temperature
-20ºC~+55ºC
Atmospheric pressure range
500hPa~1060hPa
Relative humidity
≤93%RH
Packing size/ Gross Weight
Base packing size: 1200*800*870mm 50Kg
Body packing size: 1100*710*855mm 60Kg
The work environment
Relative humidity
30%RH~75%RH
Environment temperature
+20ºC~+30ºC
Pressure range
700hPa~1060hPa
Service altitude
≤2000m
Overvoltage category
II
Pollution level
2
Ambient air velocity
≤ 0.3/s
Other indicators
Ambient noise in the infant compartment of the incubator
No more than 55dB(A) at stable temperature
Carbon dioxide concentration in the infant compartment
A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the
box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after
stabilization
The velocity of air flow over the baby mattress
≤0.35m/s
General
alarm
Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water
shortage alarm
System alarm
Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure
alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity
heating system failure
3. Features

1,LCD display
2,Double control modes of box temperature and skin temperature
3,Double-layer thermostatic cover, automatic air curtain device
4,Humidity control function
5,Electronic elevator
6,Air & Oxygen blender
7,Oxygen supply system
8,Baby cot is infinitely adjustable
9,26 kinds of sound and light alarm, comprehensive protection of baby safety

Company Profile

 


Company Overview:

Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II
Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II
FAQ

 

FAQ

1. How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
2. How about Biobase delivery time?
Within 7-15 workdays after receiving deposit.
3. How about Biobase validity of quotation?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
4. What's the shipping port?
FOB to Qingdao Port, China(also can ship according to customers' request)
5. How about the package?
Bubble film & cotton & standard export wooden case
6. How to inspect the goods?
Products will be checked by our QC staff first, then our project manager.
Client can come and check by themselves or by third party check is available.
Contact Us

 



Contact Me

Biobase China Baby Radiation Warming Hospital Infant Radiant Warmer Bk-3201type II

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2019

Suppliers with verified business licenses

Trading Company
Number of Employees
93
Year of Establishment
2012-06-01