Model
|
BK-GC901
|
|
Oven
|
Temp. Range
|
RT+5~450ºC
|
Temp. Accuracy
|
≤±0.01ºC
|
|
Temp. Program
|
16-phase
|
|
Max. Temp. Heating Rate
|
40ºC/min
|
|
Time Range
|
0-999.9min
|
|
Detector
|
Hydrogen Flame Ionization Detector (FID)
|
Detection limit:≤5×10-12g/s
(100ng/ul n-hexadecane-isooctane solution) |
Temperature 450ºC
|
||
Compatible with packed and capillary columns
|
||
Baseline drift:≤2x10-13A/30min
|
||
Baseline noise: 3×10-14A
|
||
Linear range:≥107
|
||
Thermal Conductivity Detector (TCD)
|
Sensitivity: >5000mv.ml/mg
(50mg/ml toluene-benzene solution) |
|
Temperature 400ºC
|
||
Baseline drift:≤0.1mV/30min
|
||
Baseline noise: 0.03mV
|
||
Linear range:≥105(±10%)
|
||
Electron Capture Detector (ECD)
|
Detection limit:≤1×10-14g/ml
(Sample: n-hexadecane δ-666) |
|
Linear range: ≥104
|
||
Flame Photometric Detector (FPD)
|
Detection limit:≤5×10-12g/s(S of 10ng/uL methyl parathion-ethanol solution)
Detection limit:≤4×10-12g/s(P of 10ng/uL methyl parathion-ethanol solution) |
|
Linear range (S): ≥103
Linear range (P): ≥104 |
||
Temperature 350ºC
|
||
Nitrogen and Phosphorus Detector (NPD)
|
Detection limit:≤1×10-12g/s (Azobenzene)
Detection limit:≤1×10-12g/s(Marla sulfur phosphorous) |
|
Linear range: ≥103
|
||
Injection Method
|
Capillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid
automatic sampling system, etc. |
|
Inlet
|
1~4, up to 3 capillary column inlets
|
|
Injection Type
|
Packed column injection, capillary column injection. (Flow setting range: 0~1000ml/min)
|
|
Control Accuracy
|
Pressure: 0.01KPa; Flow: 0.01ml/min
|
|
Maximum Split Ratio
|
1:999
|
|
Pressure Sensor
|
Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa
|
|
Flow Sensors
|
Accuracy: < 5% of full scale; Repeatability: 0.5K Pa (full scale); Output offset (accuracy): ±5%
|
|
Sampling Valve
|
Can be equipped with multiple imported automatic control valves, which can run automatically in sequence
|
|
Power Supply
|
AC220V±10%, 50/60Hz
|
|
Standard Accessory
|
FID detector, Chromatography workstation software, Capillary sampler
|
|
Optional Accessory
|
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
|
|
Package Size (W*D*H)
|
750*710*720 mm
|
|
Gross Weight
|
70kg
|